Excel CPC 100 File Loader
15 - 3
Template Usage
Templates are pairs of XML documents and Microsoft Excel templates designed
by OMICRON electronics or end users for designated applications. The XML
templates are predefined test procedures, often with comments, that run on
CPC 100
and guide the user through the test. Once completed, the XML file is
saved, downloaded to the PC using
CPC Explorer
and then loaded with
CPC100 File Loader
into the corresponding Microsoft Excel template. There the
results are post processed and a final test report is generated. The template
pairs facilitate and speed testing with
CPC 100
and the evaluation of results.
Some template pairs allow version control. If an error message appears after
loading the XML template, use a template pair of the same version. The
template usage requires the
CPC Explorer
software to be installed on your PC.
CPC Explorer
enables you to transfer files (templates and test results) between
the PC and
CPC 100
.
To run a test procedure according to a template:
1. Using
CPC Explorer
, upload a single XML template or a whole folder of
templates for the intended application from the PC to
CPC 100
.
The XML templates (
*.xmt
files) are available on the
CPC Explorer
CD-ROM in the
Templates
directory or in the customer area of
www.omicron.at.
2. Open the template on
CPC 100
.
3. Run the test procedure according to the template.
4. After completing the test procedure, save the test as a new file.
5. Using
CPC Explorer
, download the test results from
CPC 100
to your
preferred working directory on the PC.
6. Open the corresponding Microsoft Excel template by double-clicking the
*.xlt
file in the folder labeled with the test procedure name in the
Templates\CPC 100
directory.
A Microsoft Excel workbook appears.
7. Click the
Load XML-File
button and open the
*.xml
file saved in your
preferred working directory before loading the test results.
Excel CPC 100 File Loader
loads the test results from the XML file to the
Microsoft Excel template.
8. After all worksheets are filled with data, the test results are calculated and
displayed.
Summary of Contents for CPC 100
Page 12: ...CPC 100 V1 41 x...
Page 28: ...CPC 100 V1 41 1 16...
Page 90: ...CPC 100 V1 41 3 14...
Page 194: ...CPC 100 V1 41 6 30...
Page 250: ...CPC 100 V1 41 8 32 Figure 24 Settings of Amplifier test card for this example use case...
Page 258: ...CPC 100 V1 41 9 4...
Page 264: ...CPC 100 V1 41 10 6...
Page 282: ...CPC 100 V1 41 12 10 Figure 9 Saving tests with the CPC Editor...
Page 284: ...CPC 100 V1 41 12 12...
Page 312: ...CPC 100 V1 41 14 12...
Page 316: ...CPC 100 V1 41 15 4...
Page 350: ...CPC 100 V1 41 16 34...
Page 372: ...OMICRON Contact Addresses 22...