GPI/Genlock Calibrations
117
4. In the
Properties
tab, click the
SDI Output Reclocking
box, and then select
ON
or
OFF
from the list.
5. Click
Apply to all
to apply the chosen value throughout the system.
GPI/Genlock Calibrations
Calibrating GPI Lines
You can define actions that change the state of a GPI output line, and assign them to a monitor. GPI lines
configured as outputs can have their ON/OFF state set manually in XEdit, for test purposes.
To configure a GPI line’s direction as an output:
1. In the main window, click the
System
tab, and then click
Description/Calibrations
on the
second-level tab bar.
A hierarchical list representing the current system appears.
2. In the list, expand the multi-viewer you wish to calibrate.
3. Expand the GPI/GENLOCK module, and then click the appropriate GPI line element.
4. In the
Properties
tab, click the
GPI Direction
box, and then select
output
from the list.
5. Click
Apply to all
, if every GPI line in your system is to be configured as an output.
Note:
GPI direction is pre-defined on the Kaleido-X16 and KMV-3901/3911 multi-viewers.
Summary of Contents for Kaleido-X
Page 1: ...Kaleido X User s Manual Part Number M770 2800 111 1 June 2011 ...
Page 8: ...viii toc ...
Page 33: ...Loading a Layout 25 Kaleido X16 ...
Page 34: ...26 Getting Started 2 Kaleido X 4RU ...
Page 152: ...144 Creating Logical Sources 7 ...
Page 178: ...170 Setting Up Rooms 8 ...
Page 244: ...236 Creating Layouts 9 ...
Page 253: ...Detailed Directions 245 3 Under Properties General type a Friendly name for the Action ...
Page 256: ...248 Creating Actions 10 ...
Page 272: ...264 Managing Kaleido RCP2 Users 11 ...
Page 348: ...340 Tally Interface Devices 13 ...
Page 350: ......
Page 352: ...344 Using the Serial to TCP IP Dispatcher 15 ...
Page 406: ...398 Index ...