Installation
2 - 47
Standard Turntable Power Washer v. 4.0
The MART Corporation
On each pump motor, find the manufacturer's specification tag.
The tag indicates two things:
(1)
Full-load amperage draw at
your specified voltage; and
(2)
The service factor, which is
stamped on the motor nameplate
Multiply the full-load draw (as indicated on the motor tag) by
the service factor in order to calculate the maximum allowable
amp load.
The actual amperage draw reading on each motor is to fall
below
the maximum calculated allowable amp load.
Cycling Test
:
Perform the cycling test
after
the reservoir has filled,
and after
the
washer has fully heated.
During winter
, "water hammer" may
occur more frequently, or be more severe, due to lower ambient
temperatures. If these conditions are true, increment the Wash
Delay timer settings until "water hammer" stops. Refer to steps #8
and #9 below.
Note: Water hammer is the result of cool air entering a hot enclosure. When
the pump system comes on, this cool air is rapidly heated by the hot water
solution, which results in a rapid expansion in excess of the normal exhaust
system capacity. The excess air pressure generated may cause hot solution
to be ejected from the washer.
8. Open washer cabinet door wide open for a minimum of 30 seconds. Close
and latch the door.
9. Stand to the side of the washer, and press the
start
button.
10. If water is ejected from under the front reservoir cover:
·
Press the
stop
button.
·
Add additional time to the wash delay timer
·
Repeat steps #8 thru #10 until the water ejection stops.
11. Verify the factory pre-set times for the optional Auto Rinse Cycle (ARC), and
the Auto Steam Exhaust (ASE) timers per the following tables.
Timer for:
Factory Setting:
Auto Rinse Cycle, (ARC)
1 minute
Auto Steam Exhaust, (ASE)
1 minute
Additional Operational Checks:
11. With machine running a wash cycle, manually depress the float rod down.
Verify wash cycle stops immediately. Wash cycle should not be able to be
able to be restarted until float rod is released and allowed to return to it’s
Summary of Contents for Cyclone 30 Series
Page 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Page 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Page 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Page 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...