4 - 8
Installation, Operations, and Maintenance Manual
The MART Corporation
Standard Turntable Power Washer v. 4.0
Temperature
Test and adjust the washer's operating temperature to determine
what is optimal for your chemical. Remember that altitude, water
hardness, and types of soils can also affect the temperature-and-
chemical reaction. Refer to section
"Temperature Adjustment"
in
this chapter.
If you need to discuss your application(s) and requirements, call
your MART representative or contact your chemical supplier.
1.5.2.
Supersaturation of Solution
The MART Power Washer is a closed-loop cleaning system. It re-uses the cleaning
solution without discharging it for treatment or disposal.
When the cleaning solution is fully saturated with greases and oils, merely adding more
chemical will not improve cleaning results -- the volume of emulsified greases and oils is
greater than the grease to be removed and has no where to go. This condition is called
supersaturation of solution
.
To correct this problem, you must remove
greases and oils
from the solution. Allow
solution to cool and oils to rise to surface, then:
·
Manually skim greases and oils from the front reservoir; change the
solution.
- Or -
·
Run the optional
Oil Skimmer
device. If you have purchased one
from MART, refer to chapter
"Options"
in this manual.
As part of the sludge clean-out procedure, you will clean out/re-charge the power
washer with chemical. Refer to chapter
"Maintenance"
for the sludge clean-out
procedure.
1.6. Charging the Power Washer with Chemical
Refer to chapter
"Installation,"
section
"Startup Procedure, Chemical-Charging"
for
instructions.
1.7 Corrosion Protection
Since alkaline cleaners are non-corrosive to ferrous metals the cost to manufacture
cleaning equipment can be reduced. Stainless steel is not required for construction and
protection of the reservoirs, pumps, tanks, cabinets and turntables. In fact carbon steel
can be used for the reservoirs and cabinets with no detrimental effects as long as the
concentration of alkalinity is maintained. With proper mantainance of your chemcial
Summary of Contents for Cyclone 30 Series
Page 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Page 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Page 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Page 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...