5 - 12
Installation, Operations, and Maintenance Manual
The MART Corporation
Standard Turntable Power Washer v. 4.0
5.
Add approximately
1 ounce (2.9 ml) of fresh grease
(which is about
2-3
hand-pumps of grease
).
6.
Turn the
main power supply ON
.
2.1.8.
Wash Pump Couplings (Inspect)
Inspect the wash pump(s) couplings for the following:
·
Wear
·
Separation
·
Misalignment
Refer to Fig. 5-6 as you inspect couplings for the following:
Wear
If couplings are worn, replace them.
Separation
If couplings are separated, loosen them and re-adjust their
position.
Misalignment
If couplings are misaligned, they are also probably worn or
separated. Loosen the couplings and re-adjust their position.
Also, check the bolts for tightness.