2 - 38
Installation, Operations, and Maintenance Manual
The MART Corporation
Standard Turntable Power Washer v. 4.0
5. Verify by visual inspection or by sound that the washer reservoir begins to fill
with water (the water-fill solenoid should open when you turn the main power
supply and the clock-override switch ON). Refer to Fig. 2-7 for the water-
supply connection location.
6. Set the ASE Timer to 1 minute or any desired time between 0-10 minutes.
7. After about two hours, check the washer reservoir to verify or adjust the set-
point water level. (While the reservoir fills, you can continue with the power-
up procedure.)
Water-Level Control:
The water-level control system is fully installed in the power washer and requires
only verification that the set-point water level is correct for operation of the machine.
Follow these steps to verify or adjust the set-point water level:
1. Remove the float control box cover by removing four (4) screws. Refer to the
following figure:
Fig. 2 - 16: Float Control Box
Cam Set
Screws
Float Cam
Lower Limit
Switch FS-2
Upper Limit
Switch FS-1
Float
Rod
Summary of Contents for Cyclone 30 Series
Page 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Page 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Page 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Page 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...