5 - 20
Installation, Operations, and Maintenance Manual
The MART Corporation
Standard Turntable Power Washer v. 4.0
4.
Use clean labratory flasks, vials, and bottles for all titrations.
Dirty tools can produce invalid test results.
5.
After testing the sample, pour it back into the washer.
For improved testing accuracy:
1.
Prepare a "control" sample using fresh city water and
chemical to the desired concentration.
2.
Titrate this "control" sample.
3.
Compare titrations of the wash solution to the results of the
"control" in order to determine if you need to add chemical.
2.
Conductivity Test (optional)
If your washer is equipped with optional conductivity-test
instruments, refer to chapter
"Options,"
section
“Chemical
Concentration Controller,”
for information on performing a
conductivity test.