2 - 28
Installation, Operations, and Maintenance Manual
The MART Corporation
Standard Turntable Power Washer v. 4.0
Note
: The ASE blower assembly comes with a 1/12-HP motor. If
your steam exhaust vent pipe exceeds 30 feet (9 m), a 1/4-HP
motor is required and can be obtained from MART. If your vent
pipe is extremely long, or if there is extreme negative pressure in
your shop area, MART may need to assist you in determining the
proper size venturi blower and motor assembly. (When calculating
pipe length, each 90
°
-angle bend equals 10 feet [3 m] of straight
pipe.)
CAUTION! You must mount the ASE assembly in line with the
steam-exhaust pipe, and as far away from the washer as
possible, at least 20ft. if possible. – It’s best to install where
the steam-exhaust pipe leaves the building. Do not install ASE
assembly directly on top of the washer!
CAUTION! If you are mounting the Venturi Tube in a
horizontal position, mount it such that the fan is above the
tube 45
°
from the vertical, as shown in the following figure.
Fig. 2 - 12: Mounting the ASE Fan on a horizontal mounted Venturi Tube
Refer to the following figure for instructions on piping and blower installation.
Summary of Contents for Cyclone 30 Series
Page 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Page 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Page 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Page 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...