Installation
2 - 15
Standard Turntable Power Washer v. 4.0
The MART Corporation
5.2. Connection Procedures - Input
This section describes
input
connection procedures. The next section describes
output
connection procedures.
Use your placement plan and the SBO form to determine which of the following utility
connections you must make.
Input Utility Connections:
·
Heat source
·
Gas (natural and propane)
·
Electric
·
Steam
·
Water
·
Compressed air
·
Electricity
Depending on your power washer configuration and optional equipment, refer to the
applicable sections in this manual for information on making the necessary connections.
5.2.1.
Heat Source
Depending on the washer's configuration and options, it will use one of the following
heat sources:
·
Gas (natural and propane)
·
Electric
·
Steam
A description of each type of heat source follows
.
Gas & Oil Heat Source
For proper connection of the gas heat source, natural or propane, refer to the
specifications in the SBO and to the vendor manual provided with the burner.
Burner Mounting
The power washer is equipped with a burner, as shown in one of the following figures.
Locate the figure that refers to your burner size.
NOTE:
After burner mounting is
completed, check to be sure there is an airtight seal between the burner and the
combustion chamber.
Summary of Contents for Cyclone 30 Series
Page 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Page 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Page 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Page 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...