5 - 16
Installation, Operations, and Maintenance Manual
The MART Corporation
Standard Turntable Power Washer v. 4.0
NOTE: If your washer has a rinse system, once operations
have started water levels in the washer can be higher than the
set-point water level. This happens whenever the washer
automatically uses the rinse-bank for longer rinses.
To verify the correct set-point water level after operations have
started, you must allow the washer to fill to the set-point. You
can check this by observing the position of the float cam
relative to the limit switches in the float box. (Refer to Fig. 1-3:
Float-Level Mechanics) If the cam is higher than the set-point,
you will have to remove solution from the washer and allow
the washer to fill to the set-point to check set-point water level.
REMEMBER!!
NEVER CHANGE
THE POSITION OF THE LIMIT
SWITCHES
-- they are pre-set. For more information on the limit
switches, refer to chapter
"Overview."
2.3.2.
Water Solenoid Valves (Clean or Replace)
Disassemble the water solenoid valves, and clean or replace the diaphragms with re-
build kits.
Refer to your vendor-supplied cut sheet for instructions.
Fig. 5 - 9: Solenoid Valves
Air
Solenoid
Valve
Compressed
Air
Inlet
Rinse
Reservoir
Drain Plug
Rinse
Water
Solenoid
Valve
Summary of Contents for Cyclone 30 Series
Page 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Page 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Page 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Page 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...