7 - 30
Installation, Operations, and Maintenance Manual
The MART Corporation
Standard Turntable Power Washer v.
4
.0
4.4. Maintenance
Every 160 hours of operation:
·
Monitor
chemical usage by the peristaltic pump. Replace the empty
barrel after the concentrate has been completely used.
·
Test
peristaltic pump operation:
1. Set the controller
LO set point
10% below the actual
solution conductivity.
2. Run a wash cycle.
3. Verify that the pump is pumping chemical into the reservoir.
4. Re-set the LO set point to your
control set point
.
Peristaltic Pump and Tubing
The pump has few moving parts, and no seals or valves to clog, clean, or replace. As
tubing fatigues (and eventually cracks), move it to a section that has not been under the
pump rollers. Then, continue pumping.
When you run low on tubing, order a new spool.
Sludge Clean-Out
During sludge clean out, clean the probe thoroughly. Follow the vendor-supplied
instructions.