Advanced Operations: Process-Control
4 - 11
Standard Turntable Power Washer v. 4.0
The MART Corporation
2. Temperature Adjustment
The recommended maximum temperature operating points are shown in the following
figure.
NOTE:
The set point on the controller can differ from the actual temperature.
Maximum Actual Operating Temperature
Altitude in Feet
Temperature
°
F
0 - 2000
190
°
F ((88
°
C)
2000 4000
185
°
F (85
°
C)
4000 5000
180
°
F (82
°
C)
5000 and above
call MART
WARNING! Do NOT exceed recommended settings, or
serious damage can occur to the wash pump (cavitation).
Fig. 4 - 1: Maximum Actual Operating Temperature
The temperature controller is located inside the electrical control panel. Refer to the
following figure.
WARNING! Disconnect power before opening the control
panel.
Fig. 4 - 2: General Layout of the Electrical Control Panel (Block Diagram)