7 - 10
Installation, Operations, and Maintenance Manual
The MART Corporation
Standard Turntable Power Washer v.
4
.0
2.2 Installation
Install the power washer as described in chapter
"Installation."
When you charge the
power washer with chemical, remember to add enough chemical to take into account
the 135 gallons (511 liters) of solution that will fill the Clean Machine's separator tank.
Clean Machine
Physical Dimensions and Capacity
Length ......5 feet, 3 inches (1.60 m)
Width........2 feet, 3 inches (.69 m)
Height.......6 feet, 2 inches (1.88 m)
Capacity ...135 gallons
(511 liters)
Follow this procedure
:
1. Set the
separator tank
by the
right side
of the
washer
. Leave enough room
for access to the burner/heating elements, and opening the cabinet door. Be
sure that when it is fully open, the door will not touch the Clean Machine.
2. Level the separator tank, if necessary. Refer to chapter
"Installation --
Leveling."
3. Anchor the separator, using 5/8-18 bolts through the welded nuts on the feet
of the tank. Refer to chapter
"Installation -- Anchoring."
4. Refer to the following figure to install
piping
between the washer and the
Clean Machine.
NOTE
: Use schedule 40 black iron pipe, stainless-steel flex hose,
or any other material suitable for 50% sodium hydroxide at 200
°
F.
(93
°
C). All connections must be leakproof.
·
Install line #1
: 1 1/2-inch-diameter pipe from the 2-inch-
diameter ball valve to the cyclone inlet.
·
Install line #2
: 2-inch-diameter pipe from the 2-inch-
diameter coupling at the Clean Machine sludge tank to the
2-inch-diameter coupling at the right rear of the washer.
·
Install line #3
: 3-inch-diameter pipe from the 3-inch-
diameter coupling on the Clean Machine tank to the 3-inch-
diameter coupling at the right rear of the washer.
NOTE:
Return pipelines to the power washer are gravity feed and
must run downhill.
Summary of Contents for Cyclone 30 Series
Page 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Page 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Page 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Page 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...