Installation
2 - 25
Standard Turntable Power Washer v. 4.0
The MART Corporation
5.3. Connection Procedures - Output
This section describes
output
connection procedures. The previous section describes
input
connection procedures.
Use the SBO form to determine which of the following utility connections you must
make.
Output Utility Connections:
·
Steam exhaust
Ø
Pipe
Ø
Fan
·
Flue pipe
·
Drain
Depending on your power washer configuration and optional equipment, refer to the
applicable sections in this manual for information on making the necessary connections.
5.3.1.
Steam Exhaust (Output)
For the size of the steam exhaust, refer to the specifications in the SBO.
The following materials can be used for steam pipe:
·
Schedule 40 or 60 PVC pipe
(see
"Prerequisites, PVC Kit,"
at the
beginning of this chapter). MART washers are set up for using PVC
pipe for the steam exhaust. Your washer and ASE (auto steam
exhaust) blower unit arrive equipped for using PVC fittings.
MART
highly recommends PVC
, because it is simpler to install, requires no
welding, is lighter, and does not rust.
·
Schedule 20 or 40 black iron pipe can be used instead of PVC.
However, it lacks PVC's advantages. If you opt to use iron pipe, you
will need special adapters to modify the flanges on the ASE blower
unit.
The following steam-exhaust
installation instructions assume the use of PVC pipe
.
If you use iron pipe instead, installation steps will be similar to those given here.
However, you will have to adapt and modify flanges and fittings as necessary to
complete the assembly.
NOTE:
If your washer is equipped with a hot-air blow-off (HABO) system, refer to that
option for special instructions for steam-exhaust installation.
Summary of Contents for Cyclone 30 Series
Page 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Page 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Page 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Page 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Page 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...