MERLIN LEGEND Communications System Release 5.0
Feature Reference
555-650-110
Issue 1
June 1997
Features
Page 586
System Renumbering
The system offers three numbering plans:
■
2-Digit
■
3-Digit
■
Set Up Space
Each of the plans allows renumbering of all or selected extensions (single or
block). The system numbering plans, with the numbers they automatically assign,
are shown in Figures
through
and are described in the next three sections.
NOTE:
through
show the default settings in the gray spaces.
Extensions can be renumbered to any number shown in the white spaces.
2-Digit Numbering Plan
3
9
The 2-digit numbering plan is the factory setting. This plan is designed for
companies that do not anticipate a need for more than 50 extensions in the next
one or two years.
shows the numbers automatically assigned by the system. The
are arranged in rows according to the first digit. The type of
equipment, jack, or feature to which they are assigned is indicated within the row.
*
Listed Directory Number (QCC Queue)
†
Remote Access
Figure 43.
2-Digit Numbering Plan
0
Operator Console (not flexible) 0
1
Extensions 10–19
2
Extensions 20–29
3
Extensions 30–39
4
Extensions 40–49
5
Extensions 50–59
6
Extensions 60–66
Extra Extensions
6700–6842
6843–6849
Extra MFMs/
Terminal
Adapters
6850–6992
6993–6999
7
Main Pool
70
Adjuncts
710–766
767– 769
Calling Groups
770–791,7920–7929
Paging Groups
793–799
8
800*
Lines/Trunks 801–880
Park
881–888
889†
Pools
890–899
9
ARS Access (Hybrid/PBX Mode) / Idle Line Access 9