Integrated Administration
Application Switch Defaults Screen
2
5
A technician reaches the Application Switch Defaults screen from the Technician
Maintenance menu.
shows this screen when only AUDIX Voice Power
is installed and when both AUDIX Voice Power and Fax Attendant are installed.
The values shown in the screens in
are the defaults for all information
on the Application Switch Defaults screen. When a user accesses the screen, the
current programmed values are shown.
The settings in the Current Switch column for Reliable Disconnect, Delay Ring,
Coverage Delay Ring, VMS Transfer Return Interval, and Transfer Return Time
are displayed for comparison purposes and cannot be changed on this screen.
The values in the AVP Default column can be changed, and are sent to the switch
when the user presses
(Save). A difference between the two columns, other
than at initial installation, indicates that the values have been changed through
system programming on the system, using the programming console or SPM.
Knowing this can be helpful in troubleshooting problems.
NOTE:
The calling group numbers and coverage group number displayed on this
screen (including any changes made) are the values used for the
information sent to the system when services are programmed on the
System Programming/Switch Admin Form screen,
,
and when subscribers are added to the AUDIX Voice Power coverage
group on the AUDIX Voice Power User or AUDIX Voice Power/Fax
Attendant User screen,
. Therefore, if any of these
group numbers must be changed, make changes
first
, before programming
services or subscribers.
If it is necessary to change any calling group numbers
after
initial programming of
the services, make the changes in the following order:
1.
Remove the affected services by deleting those services from all channels
on the System Programming/Switch Admin Form screen.
2.
Change the appropriate calling group numbers on the Application Switch
Defaults screen.
Table 25.
Continued
Label Key
Action
PrevPage
On a multiple-page screen, return to the previous page.
Prev-Rec
Display the previous record, such as the previous extension, on
the current screen.
Save
Validate and save the information on the current screen, updating
the application database and/or the switch as appropriate.