5.34 Read, Write, and Save Parameters
Use read, write, and save function parameters on the inverter to copy parameters from the
inverter to the keypad or from the keypad to the inverter.
Group Code
Name
LCD Display
Parameter Setting Setting Range Unit
CNF
46
Parameter read
Parameter Read 1
Yes
-
-
47
Parameter write
Parameter Write
1
Yes
-
-
48
Parameter save
Parameter Save
1
Yes
-
-
Read, Write, and Save Parameter Setting Details
Code
Description
CNF-46 Parameter
Read
Copies saved parameters from the inverter to the keypad. Saved
parameters on the keypad will be deleted and replaced with the copied
parameters.
CNF-47 Parameter
Write
Copies saved parameters from the keypad to the inverter. Saved
parameters on the inverter will be deleted and replaced with the copied
parameters. If an error occurs during parameter writing, the previously
saved data will be used. If there is no saved data on the Keypad, ‘EEP
Rom Empty
’ will be displayed.
CNF-48 Parameter
Save
As parameters set during communication transmission are saved to
RAM, the setting values will be lost if the power goes off and on. When
setting parameters during communication transmission, select ‘1 (Yes)’
at CNF-48 to save the set parameter.
5.35 Parameter Initialization
User changes to parameters can be initialized (reset) to factory default settings on all or
selected groups. However, during a fault trip situation or operation, parameters cannot be
reset.
Group Code Name
LCD Display
Parameter Setting Setting Range Unit
CNF
40
Parameter initialization
Parameter Init 0
No
0
–15
Summary of Contents for LSLV-H100 Series
Page 17: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Page 18: ...Preparing the Installation 5 110 132 kW 3 Phase ...
Page 19: ...Preparing the Installation 6 160 185 kW 3 Phase ...
Page 20: ...Preparing the Installation 7 220 250 kW 3 Phase ...
Page 21: ...Preparing the Installation 8 315 400 kW 3 Phase ...
Page 22: ...Preparing the Installation 9 500 kW 3 Phase ...
Page 35: ...Installing the Inverter 22 ...
Page 50: ...37 Installing the Inverter Input and Output Control Terminal Block Wiring Diagram ...
Page 104: ...91 Learning Basic Features 0 10 V Input Voltage Setting Details V1 Quantizing ...
Page 181: ...168 Learning Advanced Features PID Command Block ...
Page 182: ...169 Learning Advanced Features ...
Page 183: ...170 Learning Advanced Features PID Feedback Block ...
Page 184: ...171 Learning Advanced Features PID Output Block ...
Page 185: ...172 Learning Advanced Features PID Output Mode Block ...
Page 198: ...185 Learning Advanced Features EPID1 Control block ...
Page 199: ...186 Learning Advanced Features EPID2 Control block ...
Page 220: ...207 Learning Advanced Features ...
Page 235: ...222 Learning Advanced Features The Time Chart for the Exception Day ...
Page 506: ...Table of Functions 493 ...
Page 520: ...Table of Functions 507 8 16 4 Cooling Tower MC4 Group ...
Page 549: ...Troubleshooting 536 ...
Page 569: ...Technical Specification 556 11 3 External Dimensions 0 75 30 kW 3 phase 37 90 kW 3 phase ...
Page 570: ...Technical Specification 557 110 185 kW 3 phase ...
Page 601: ...588 ...
Page 602: ...589 ...
Page 603: ...590 ...