5
1
KEB COMBIVERT F5-M / S
4
Name: Basis
18.05.04
Parameter
Chapter
Section
Page
Date
©
KEB Antriebstechnik, 2002
All Rights reserved
5.1.3
F5-GENERAL
Control
B-housing
This control card is used for housing size B.
The parameters In.8 and In.9 are only
available at this control card.The following parameters are not available, so they do
not need to be considered in the parameter description:
5.1.2
F5-BASIC
Control
This control card is used for all housing sizes. Following parameters are not available
with the control F5-BASIC, so they do not need to be considered in the parameter
description:
ru 4 encoder 1 frequency
ru 5 encoder 2 frequency
ru 6 calculated act. freq.
ru 7 actual value display
ru 9 encoder 1 speed
ru 10 encoder 2 speed
ru 31 AN3 pre amplifier disp.
ru 32 AN3 post amplifier disp.
op44 ext. funct. mode/src
op45 ext. funct. dig. source
op46 ext. funct. acc/dec time
op47 sweep-gen. acc. time
op48 sweep-gen. dec. time
op49 diam. corr. dmin/dmax
op51 motorpoti destination
an20 AN3 interface selection
an21 AN3 noise filter
an22 AN3 save mode
an23 AN3 save trig. inp. sel.
an24 AN3 zero clamp
an25 AN3 gain
an26 AN3 offset X
an27 AN3 offset Y
an28 AN3 lower limit
an29 AN3 upper limit
in 5 interface type
in 17 temp.- mode
cs 1 act. source
dr 3 DASM rated power
ec 0 encoder 1 interface
ec 1 encoder 1 (inc/r)
ru 4 encoder 1 frequency
ru 5 encoder 2 frequency
ru 6 calculated act. freq.
ru 7 actual value display
ru 9 encoder 1 speed
ru 10 encoder 2 speed
ru 29 AN2 pre amplifier disp.
ru 30 AN2 post amplifier disp.
ru 31 AN3 pre amplifier disp.
ru 32 AN3 post amplifier disp.
ru 35 ANOUT2 pre ampl. disp.
ru 36 ANOUT2 post ampl. disp.
an10 AN2 interface selection
an11 AN2 noise filter
an12 AN2 save mode
an13 AN2 save trig. inp. sel.
an14 AN2 zero clamp
an15 AN2 gain
an16 AN2 offset X
an17 AN2 offset Y
an18 AN2 lower limit
an19 AN2 upper limit
an20 AN3 interface selection
an21 AN3 noise filter
an22 AN3 save mode
an23 AN3 save trig. inp. sel.
an24 AN3 zero clamp
an25 AN3 gain
an26 AN3 offset X
an27 AN3 offset Y
an28 AN3 lower limit
an29 AN3 upper limit
an36 ANOUT2 function
an37 ANOUT2 value
an38 ANOUT2 gain
an39 ANOUT2 offset X
an40 ANOUT2 offset Y
di 0 PNP / NPN selection
do25 inv. flags for O1
do26 inv. flags for O2
do33 flag select. for O1
do34 flag select. forO2
in 8 software version p. unit
in 9 software date p. unit
ec 3 time 1 for speed calc.
ec 4 gear 1 numerator
ec 5 gear 1 determinator
ec 6 enc.1 rotation
ec 7 enc.1 trigger
ec10 encoder 2 interface
ec11 encoder 2 (inc/r)
ec13 time 2 for speed calc.
ec14 gear 2 numerator
ec15 gear 2 determinator
ec16 enc.2 rotation
ec17 enc.2 trigger
ec20 enc.2 operating mode
ec21 SSI multiturn res.
ec22 SSI clock frq. sel.
ec23 SSI data code
ec25 nominal tacho speed
ec27 operation mode output
aa14 evaluation para 1
aa15 evaluation para 2
aa16 evaluation para 3
aa17 evaluation para 4
aa18 evaluation para 5
aa19 evaluation para 6
aa20 evaluation para 7
aa21 evaluation para 8
aa22 evaluation para 9
aa23 evaluation para 10
aa24 evaluation para 11
aa25 evaluation para 12