6
9
7
KEB COMBIVERT F5
Name: Basis
04.05.04
6
Section
Page
Date
©
KEB Antriebstechnik, 2002
All rights reserved
Chapter
Functional Description
Special Functions
-100%
100%
oP.54
oP.55
0%
oP.53
t
oP.59
oP.59
oP.59
oP.59
1
0
An.53
An.55
An.56
6.9.3
Motor Potentiome-
ter Function
This function simulates a mechanic motor potentiometer. Over two inputs the motor
potentiometer value can be increased or decreased.
Fig. 6.9.3
Motor potentiometer function
Bit Value Input
Terminal
0
1
ST (Prog. input „Control release/Reset“)
X2A.16
1
2
RST (Prog. input „Reset“)
X2A.17
2
4
F (Prog. input „forward“)
X2A.14
3
8
R (Prog. input „reverse“)
X2A.15
4
16
I1 (Prog. input 1)
X2A.10
5
32
I2 (Prog. input 2)
X2A.11
6
64
I3 (Prog. input 3)
X2A.12
7
128
I4 (Prog. input 4)
X2A.13
8
256
IA (Internal input A)
none
9
512
IB (Internal input B)
none
10
1024
IC (Internal input C)
none
11
2048
ID (Internal input D)
none
oP.50 Motor potentiometer / Function
Bit 1 Bit 0
Meaning
x
0
Value is changed in the current set
x
1
Value is changed only in set 0
0
x
No motor poti reset after Power-on
1
x
Reset on oP.55 after Power-on
oP.56 Input selection
Increase motor poti value
oP.57 Input selection
Decrease motor poti value
oP.58 Input selection
Reset on oP.55
oP.52 Motor poti / Value
Presetting via parameter
±100%
(oP.59 is being ignored)
ru.37 Display motor poti value
-100...0...100 %
Rotation direct.
+ = forward
- = reverse
Setpoint
to oP.0
value „4“
to oP.1 value „6 u. 7“
Aux
Parameter setting by the
motorpoti / aux function
An54 Target analog
Parameter settings
see chapter 6.9.10