Functional Description
Special Functions
Analog parameter setting
mode (An.53)
This parameter determines whether the analog parameter setting occurs via the motor-
poti or the aux-function.
an.53 Function
0 AUX
1 Motor-poti function
The Bus-address of the parameter, that is to be adjusted in analog mode, is adjusted
here (see Chapter 5). Following parameters can be adjusted:
uF.1 / 7
cn. 4 / 5 / 6
An.32 / 37 / 42 / 48
LE.0 / 1 / 2 / 3 / 4 / 5 / 6 / 7
cS.6 / 9
Ec.4 / 14
In case an invalid parameter address is selected, the message „IdAtA“ (or „data inva-
lid“ at COMBIVIS) is output and the setting is ignored.
Defines the parameter value, that adjusts itself at 0 % analog parameter setting. The
parameter value must be entered with the internal standardization of the target parameter.
Desired value of target parameter
Value to be adjusted = --------------------------------------------------------
Resolution of target parameter
Defines the parameter value, that adjusts itself at 100 % analog parameter setting.
The parameter value must be entered with the internal standardization of the target
parameter.
An.57 determines the parameter set in which the selected parameter is changed. If a
programmable parameter is adjusted as target, the adjusted set in An.57 is changed.
An.57 Function
-1
aktive set is changed
0...7 adjusted set is changed
Independent from parameter An.57 a change in set 0 is done always, if a non-
programmable parameter is adjusted as target.
Analog parameter setting
destination (An.54)
Analog parameter setting
Offset (An.55)
Analog parameter setting
max. Value (An.56)
Used Parameters
6.9.10 Analog setting of
parameter values
With this function it is possible to preset parameter values analog. The AUX-function or
the motor-poti function can be adjusted as source.
Parameter
Adr.
ro prog
min
max
default
[?]
Remarks
An.53Analog para. setting mode
0A35 -
-
yes
0
1
1
0
-
An.54an. para setting destination
0A36 -
-
yes
-1: oFF
7FFFh
0001h
-1: oFF
-
An.55an. para setting offset
0A37 -
-
yes
-2
31
2
31-1
1
0
-
An.56an. para set. max. value
0A38 -
-
yes
-2
31
2
31-1
1
0
-
An.57an. para setting set pointer
0A39 -
-
yes
-1
7
1
0
-
Analog parameter setting
set pointer (An.57)