4
CP - Parameter
Operation
4
3
9
KEB COMBIVERT F5-M / S
Name: Basis
17.05.04
Section
Page
Date
©
KEB Antriebstechnik, 2003
All Rights reserved
Chapter
F5-MULTI:
DASM rated current
Adjustment of the rated motor current according to the name plate and the connection
(Y /
∆
). The factory setting depends on the unit size (see 4.3.7 ÑFactory Settingsì).
Adjustment range:
0,0...710,0 A
Resolution:
0,1 A
Factory setting:
LTK
F5-MULTI:
DASM rated frequency
Adjustment of the rated motor frequency according to the name plate. The factory
setting depends on the unit size (see 4.3.7 ÑFactory Settingsì).
Adjustment range:
0,0...1600,0 Hz
Resolution:
0,1 Hz
Factory setting:
LTK
F5-MULTI:
DASM rated speed
Adjustment of rated motor speed according to the name plate. The factory setting
depends on the unit size. (see 4.3.7 ÑFactory Settingsì).
Adjustment range:
0...64000 rpm
Resolution:
1 rpm
Factory setting:
LTK
F5-SERVO:
DSM rated torque
Adjustment range:
0,1...6553,5 Nm
Resolution:
0,1 Nm
Factory setting:
LTK
Adjustment of rated motor torque according to the name plate. The factory setting
depends on the motor.
F5-SERVO:
DSM rated speed
Adjustment of the motor rated speed according to the name plate. The factory setting
depends on the motor.
Adjustment range:
0...32000 rpm
Resolution:
1 rpm
Factory setting:
LTK
F5-SERVO:
DSM rated frequency
Adjustment of the rated motor frequency according to the name plate. The factory
setting depends on the motor.
Adjustment range:
0,0...1600,0 Hz
Resolution:
0,1 Hz
Factory setting:
LTK