6
9
KEB COMBIVERT F5
32
Name: Basis
04.05.04
Chapter
Section
Page
Date
©
KEB Antriebstechnik, 2002
All rights reserved
Functional Description
Special Functions
Exsample 1
The drive runs a distance, positions and remains at the stop position for a time. The
new cycle starts.
Download list:
Set
Parameter
Value
Notes
0
Ud01
Password
440
0
Fr01
Copy parameter set
-2: def. cust.para all sets
0-1
oP00
Reference source
0: Analog REF
0
oP01
Rotation source
2: F/R, 0-lim.
Set 0: running
1
oP01
Rotation source
0: dig., 0-lim.
Set 1: positioning
1
oP02
Rotation setting
0: low speed
0-1
oP10
Max. reference forward
70,0000 Hz
The max. setpoint value must be the
same in all sets.
0-1
oP28
Acc. time forward
0,01 s
0-1
oP30
Dec. time forward
0,20 s
0
Pn63
Positioning delay
-1: off
1
Pn63
Positioning delay
5,00 s
Shifting of the stop position
0
Fr02
Parameter set source
3: term. inp. coded ST-I1-ID
0
Fr05
Set activation delay
1,00 s
Additonal break at the stop position
1
Fr05
Set activation delay
0,00 s
This time must be = 0
0
Fr06
Set deactivation delay
0,00 s
This time must be = 0
1
Fr06
Set deactivation delay
2,55 s
Break at the stop position
0
Fr07
Para. set input selection
16: I1
0
di11
I1 Function
2048: Set selection initiator signal