6
1
KEB COMBIVERT F5-M / S
18
Name: Basis
12.05.04
Chapter
Section
Page
Date
©
KEB Antriebstechnik, 2002
All Rights reserved
Functional Desription
Operating and Unit Data
This parameter displays the actual angular difference between master and slave.
Adr.
min
max
default
023Ah
ru.58
Angular difference
1
Inc
-
This parameter displays the actual factor of the rotor adaption.
Adr.
min
max
default
023Bh
ru.59
Rotor adaption factor
1
%
-
100
0
2147483647
-2147483648
This parameter displays the actual position index of the position profile.
Adr.
min
max
default
023Ch
ru.60
Actual position index
1
-
-
255
0
This parameter displays the target position of the actual position index.
Adr.
min
max
default
023Dh
ru.61
Target position
1
Inc
-
2147483647
-2147483648
This parameter displays the speed of the actual position index.
Adr.
min
max
default
023Fh
ru.63
Profil speed
0,125
rpm
-
4000
-4000
This parameter displays the rated dc link voltage automatically detected by the inverter. The value is detected at power-
on.
Adr.
min
max
default
0244h
ru.68
Rated DC voltage
1
V
-
1000
0
This parameter displays the distance to the zero signal after relieving the reference switch.
Adr.
min
max
default
0245h
ru.69
Distance reference - zero point
1
Inc
-
-2147483647
-2147483648