Parameter Sets
6.8.5
Copying of Para-
meter Sets via
Keyboard (Fr.1)
0
✳
Fr
·
1
1
✳
Fr
·
1
2
✳
Fr
·
1
3
✳
Fr
·
1
4
✳
Fr
·
1
5
✳
Fr
·
1
6
✳
Fr
·
1
7
✳
Fr
·
1
▲
DOWN
UP
▼
Adjust target set
With the keys UP/DOWN and at
flashing point the target set is adju-
sted in addition to the parameter set
number. The active (A) parameter set
must not be adjusted as target set
while copying. If the target set is > 0,
only the programmable parameters
are overwritten!
A
✳
Fr
·
1
1
2
3
4
5
6
7
▲
DOWN
UP
▼
Adjust source set
The source set is adjusted with the keys
UP/DOWN. The copying process is started
with „Enter“. Copying is only possible with
opened control release or error, otherwise
„I_oPE“ appears in the display (invalid
operation).
After copying „PASS“ appears in the display
and could be erase by „ENTER“.
0
dEF_S
➱
Changeover to source
➱
with Funct.
By loading the factory setting
all definitions defined by the
mechanical engineer are
reset! This can comprise the
ter minal assignment, set
changeover or operating states.
Before loading the default set it
is to be ensured that no
unintended operating states
occur.
ini_A
ini_S
dEF_A
Target Set Source Set Action
0...7
0...7
All programmable parameters (System parameters too)
of the source set are copied into the target set.
0
-1: dEF_S
Default values are copied into all parameters of set 0
(with the exception of System and Security parameters).
1...7
-1: dEF_S
Default values are copied into all programmable
parameters of the target set (with the exception of Sy-
stem and Security parameters).
all
-2: dEF_A
Default values are copied into all parameters of all sets
(with the exception of System and Security parameters).
0
-3: ini_S
Default values are copied into all parameters of set 0
(with the exception of Security parameters).
1...7
-3: ini_S
Default values are copied into all programmable
parameters of the target set (with the exception of
Security parameters).
all
-4: ini_A
Default values are copied into all parameters of all sets
(with the exception of Security parameters).
6.8.6
Copying of Para-
meter Sets via
Bus (Fr.1, Fr.9)
In the case of indirect set addressing at Bus operation two parameters are responsible
for the copying of parameter sets. Fr.9 defines the target set. Fr.1 defines the source
parameter set and starts the copying process. Parameter Fr.9 is not visible via
keyboard. In the case of direct set programming the source set (Fr.1) is copied into
the selected parameter sets. The following copying actions can be practised: