11
1
4
Name: Basis
KEB COMBIVERT F5
04.05.04
©
KEB Antriebstechnik, 2002
All rights reserved
Chapter
Section
Page
Date
Network Hardware
Networks
PIN
Signal
Meaning
1
–
Reserved
2
TxD
Transmission signal/RS232
3
RxD
Receive signal/RS232
4
RxD-A (+) Receive signal A/RS485
5
RxD-B (-) Receive signal B/RS485
6
VP
Supply voltage -Plus +5V (I
max
=10mA)
7
GND
Data reference potential; earth for VP
8
TxD-A (+) Transmission signal A/RS485
9
TxD-B (-)
Transmission signal B/RS485
11.1.4 Interface-Operator
00.F5.060-2000
A potential-separated RS232/RS484 interface is integrated in the interface operator
(00.F5.060-2000). The telegram structure is compatible to protocol DIN 66019 and ANSI
X3.28 as well as to protocol expansion DIN 66019 II.
RS232/RS485
5
4
3
2 1
9
8
7
6