4
CP - Parameter
Operation
4
3
5
KEB COMBIVERT F5-M / S
Name: Basis
17.05.04
Section
Page
Date
©
KEB Antriebstechnik, 2003
All Rights reserved
Chapter
LTK: depending on power circuit
Due to the calculation / measuring accuracies, tolerances with the current and torque displays as well as with
the switching levels and limitations, must be taken into consideration. The given tolerances (see parameter
description) refer to the respective maximum values with the dimensioning
KEB COMBIVERT: Motor = 1:1.
Dependent on the data from the motor manufacturer, larger tolerances at the torque displays are
possible, due to the usual variations in the machine parameters and temperature drifts.
F5-SERVO:
CP.0
password
0...9999
1
-
-
-
ud.1
CP.1
encoder 1 speed
±4000
0,125
0
rpm
-
ru.9
CP.2
set value display
±4000
0,125
0
rpm
-
ru.1
CP.3
inverter state
0...255
1
0
-
-
ru.0
CP.4
apparent current
0...6553,5
0,1
0
A
-
ru.15
CP.5
peak apparent current
0...6553,5
0,1
0
A
-
ru.16
CP.6
actual torque display
±10000,00
0,01
0
Nm
-
ru.12
CP.7
actual DC voltage
0...1000
1
0
V
-
ru.18
CP.8
peak DC voltage
0...1000
1
0
V
-
ru.19
CP.9
output voltage
0...778
1
0
V
-
ru.20
CP.10
speed control configuration
4...5
1
0
-
-
cs.0
CP.11
DSM rated torque
0,1...6553,5
0,1
LTK
Nm
-
dr.27
CP.12
DSM rated speed
0...32000
1
LTK
rpm
-
dr.24
CP.13
DSM rated frequency
0,0...1600,0
0,1
LTK
Hz
-
dr.25
CP.14
DSM rated current
0,0...710,0
0,1
LTK
A
-
dr.23
CP.15
DSM EMK voltage const.
0...1000
1
LTK
V
-
dr.26
CP.16
DSM winding inductance
0,01...500,00
0,01
LTK
mH
-
dr.31
CP.17
DSM winding resistance
0,000...50,000
0,001
LTK
Ohm
-
dr.30
CP.18
DSM curr. f. zero speed
0,0...700,0
0,1
LTK
A
-
dr.28
CP.19
load mot.dependent para.
1...2
1
1
-
E
fr.10
CP.20
absolute pos. enc.1
0...65535
1
57057
-
-
ec.2
CP.21
encoder 1 rotation
0...19
1
0
-
-
ec.6
CP.22
max. reference forward
0...4000
0,125
0
rpm
-
op.10
CP.23
step value 1
±4000
0,125
100
rpm
-
op.21
CP.24
step value 2
±4000
0,125
-100
rpm
-
op.22
CP.25
acc. time forward
0,00...300,00
0,01
5,00
s
-
op.28
CP.26
dec. time forward
-0,01...300,00
0,01
5,00
s
-
op.30
CP.27
s-curve time acc. for.
0,00...5,00
0,01
0,00
s
-
op.32
CP.28
torque reference source
0...5
1
2
-
E
cs.15
CP.29
absolute torque ref
±10000,00
0,01
LTK
Nm
-
cs.19
CP.30
KP speed
0...32767
1
300
-
-
cs.6
CP.31
KI speed
0...32767
1
100
-
-
cs.9
CP.32
switching frequency
2/4/8/12/16
-
LTK
kHz
E
uf.11
CP.33
relay output 1 / function
0...74
1
4
-
E
do.2
CP.34
relay output 2 / function
0...74
1
2
-
E
do.3
CP.35
proh. rot. stopping mode
0...6
1
6
-
-
pn.7
CP.36
E. EF stopping mode
0...6
1
0
-
-
pn.3
Display
Parameter
Adjustment range
Step
Default
Unit
Enter Source