KEB COMBIVERT F5
8
Name: Basis
04.05.04
©
KEB Antriebstechnik, 2002
All Rights reserved
Product Description
Summary
Chapter
Section
Page
Date
2.1.7
Unit Sizes 400V-Class
05
07
09
10
12
13
14
B
B
B
D
B
D
D
B
D
E
D
E
G
D
E
G
3
3
3
3
3
3
3
[kVA] 0,9 1,8
2,8
4,0
6,6
8,3
11
[kW] 0,37 0,75
1,5
2,2
4,0
5,5
7,5
[A] 1,3 2,6
4,1
5,8
9,5
12
16,5
[A] 2,3 4,7
7,4
10,4
17
21,6
18
29,7
24,8
[A] 2,8 5,6
8,9
12,5
21
25,9
21,6
35,6
29,7
[A] 1,8 3,6
6
8
13
17
23
[A] 16
16
16
16
20
25
25
[kHz] 16
16
8
8
4
16
4
8
16
4
16
2
8
16
[kHz] 16
16
16
16
4
16
16
16
6)
16
[W] 60
90 80 105 120 140 170 150 185 300 185 250 200 185 320 380
[A] 1,3 2,6
4,1
5,8
9,5
12
14,5
16,5
[A] 1,3 2,6
4,1
5,8 5,2 5,8
-
9,5
9,5
12
7,4
16,5
[A] 1,3 2,6
3,5
4,9 3,5 5,8
-
5,8 9,5 5,8
12
5,7 10 12
[
∞
C]
90
[mm
≤
] 1,5 1,5
1,5
1,5
2,5
4
4
[Ohm] 390 120
120
82
82
39 56 39 50
56
39
[Ohm] 620 620
390
270
150
110
85
[A] 2,2 7,5
7,5
10
10
21 15 21 15
15
21
1
[Nm]
0,5
1,2
0,5
1,2
Inverter Size
Housing size
Phases
Output nominal power
Max. rated motor power
Output nominal current
Max. short time current
1)
OC-tripping current
Nominal input current
Max. permissible mains fuse (inert)
Rated switching frequency
Max. switching frequency
Power loss at nominal operating
Stall current at 4kHz
2)
Stall current at 8kHz
2)
Stall current at 16kHz
2)
Max. heat sink temperature TOH
Motor line cross section
3)
Min. braking resistor
4)
Typ. braking resistor
4)
Max. braking current
Overload curve (page appendex)
Tightening torque for terminals
Mains voltage
5)
Mains frequency
Output voltage
Output frequency
Max.shielded motor line length at 4 kHz
Max.shielded motor line length at 8 kHz
Max.shielded motor line length at 16 kHz
Storage temperature
Operating temperature
Model / protective system
Relative humidity
EMC tested according to
Vibration/Jolt according to
Climatic category
[V]
305...500 ±0 (400 V Nominal voltage)
[Hz]
50 / 60 +/- 2
[V]
3 x 0...U Mains
[Hz]
see Control board
[m] 10
10
100
100
50
100
100
100
[m] 8
8
30
50
100
-
100
100
-
100
[m] 4
5
10
10
20
-
100
100
-
100
[
∞
C]
-25...70
∞
C
[
∞
C]
-10...45
∞
C
IP20
max. 95% without condensation
EN 61800-3
Germanischer Lloyd; EN 50155
3K3 in accordance with EN 50178
1) With the regulated systems F5-M as well as F5-S 5% are to be subtracted as control reserve.
2) Fuses of type Ferraz Shawmut 6,6 UD Type 31
3) Max. current before the responding of the OL2-function (only F5-M; F5-S; F5-A)
4) Recommended minimum cross section for rated power and a cable length of upto 100m (copper)
5) This data is only valid for units with internal brake transistor (see "unit identification")
6) Rated voltage 400V; at mains voltage
≥
460V multiply the rated current with factor 0.86.
7) The temperature range is only valid for the control circuit. For the power circuit the temperature range is depending on
the control cabinet installation and the cooling system.
8) 31.F5 only watercooled.