6
4
11
KEB COMBIVERT F5-M / S
Name: Basis
12.05.04
Section
Page
Date
©
KEB Antriebstechnik, 2002
All Rights reserved
Chapter
Functional Desription
Setpoint- and Ramp Adjustment
6
Fixed-value rotation direction
source (oP.18)
With oP.18 it is defined how the direction of rotation is determined in case of active
fixed value. The function and the value range correspond to oP.1.
oP.18 Rotation direction source for fixed values
0
digital via oP.2; setpoint 0-limited
1
digital via oP.2; setpoint absolute
2
terminal strip F/R; setpoint 0-limited
3
terminal strip F/R; setpoint absolute
4
terminal strip Run/Stop; setpoint 0-limited
5
terminal strip Run/Stop; setpoint absolute
6
setpoint-dependent with LS-recognition
7
setpoint-dependent without LS-recognition
8
control word SY.50; 0-limited
9
control word SY.50; 0-absolute
Fixed value input selection 1 and 2
(oP.19; oP.20)
Fixed value 1...3
(oP.21, oP.22, oP.23)
The three fixed values oP.21...23 are set-programmable and can be adjusted in the
range of -4000...4000 rpm.
Bit -No. Decimal value
Input
Terminal
0
1
ST (Prog. input ÑControl release/Resetì)
X2A.16
1
2
RST (Prog. input ÑResetì)
X2A.17
2
4
F (Prog. input ÑForwardì)
X2A.14
3
8
R (Prog. input ÑReverseì)
X2A.15
4
16
I1 (Prog. input 1)
X2A.10
5
32
I2 (Prog. input 2)
X2A.11
6
64
I3 (Prog. input 3)
X2A.12
7
128
I4 (Prog. input 4)
X2A.13
8
256
IA (Internal input A)
none
9
512
IB (Internal input B)
none
10
1024
IC (Internal input C)
none
11
2048
ID (Internal input D)
none