6
1
Name: Basis
KEB COMBIVERT F4-F
18
16.03.99
Fucntional Description
©
KEB Antriebstechnik, 1999
All Rights reserved
Chapter
Section
Page
Date
Adr.
min
max
default
1
-
0
255
0
Adr.
min
max
default
2C28h
1
-
-
63
0
Adr.
min
max
default
2C36h
1
-
-
FFFF
0
In-Parameter
In.41 Error counter OC
2C29h
In.42 Error counter OL
2C2Ah
In.43 Error counter OP
2C2Bh
In.44 Error counter OH
2C2Ch
In.45 Error counter watchdog
2C2Dh
The error counters (for E.OC, E.OL, E.OP, E.OH (E.dOH), E.buS) state the total number of the different error types that
occurred. The maximum value is 255.
s.a.
In.40 shows the error that occurred last, E. UP is not stored. The error messages are described under parameter ru.0.
In.40 Last error
The software version-number of the control processor and the control hardware is encoded in this parameter.
1. digit:
C = F4-F
2. and 3. digit:
Software version ( e.g. 14 = 1.4 )
4. digit:
Special version ( 0 = Standard)
In. 54 Software version DSP