
ANTRIEBSTECHNIK
2
©
KEB Antriebstechnik, 1998
All Rights reserved
Chapter
Section
Page
Date
2
1
7
KEB COMBIVERT F4-F
Name: Basis
11.12.98
Product Description
Summary
2.1.7 Unit Sizes 400V-Class
1)
From housing size M fuses of Type Ferra Z 6,6 URD xxx must be used.
2)
This data is only valid for units with internal brake transistor (see „2.1.4 Type Code“).
3)
At mains voltage
≥
460V multiply the nominal current with factor 0,86.
4)
These units can be used with one or more braking modules. For more informations cantact KEB.
Inverter Size
10
12
13
14
15
16
17
Output nominal power
[kVA
4
6,6
8,3
11
17
23
29
Max. rated motor power
[kW] 2,2
4
5,5
7,5
11
15
18,5
Output nominal current
[A] 5,8
9,5
12
16,5
24
33
42
Max. short-time current
[A] 10,4 17,1 21,6
18
29,7 24,8
36
49,5
63
OC-tripping current
[A] 12,7 20,9 26,4 21,6 36,3 29,7
43,2
59,4
75,6
Nominal input curren
[A] 6,4
10,5
13,2
18,1
26,5
36,5
46
Housing size
D
E
E
G
E
G
G
H
G
H
H
R
Rated operating frequency
[kHz]
8
16
16
8
16
8
16
8
16
8
16
Max.operating frequency
[kHz]
16
16
16
16
16
16
16
16
16
16
16
Power loss at nominal operating
[W] 130
180
240
200
240
260 290 360 310 490 470 700
Stall current at 8kHz
[A] 6,4
9,5
12
19
16,5
19
19
25
21,5
33
30
42
Stall current at 16kHz
[A]
-
9,5
12
12
-
12
8,5
15
9,7
20
13,5
30
Max. heat sink temperatureT
OH
[°C]
79
73
73
90
73
90
90
90
90
79
Max. permissible mains fuse (inert)
1)
[A]
10
20
20
25
35
50
63
Line cross section
[mm²] 1,5
2,5
2,5
4
6
10
16
Min. braking resistor
2)
[
Ω
] 160
50
50
39
50
39
22
25
22
22
9
Typ. braking resistor
2)
[
Ω
] 270
150
100
82
56
39
28
Max. braking current
[A]
5
15
15
21
15
21
21
37
30
37
37
88
Tightening torque for terminals
[Nm] 0,5
0,5
0,5
1,2
0,5
1,2
1,2
2,5
1,2
2,5
2,5
Mains voltage
3)
[V]
305...500 +/-0 (400V Nominal voltage)
1)
Phases
3
Mains frequency
[Hz]
50 / 60 +/- 2
Output voltage
[V]
3 x 0...U Mains
Output frequency
[Hz]
see control board
Shielded motor line length
[m]
100
Storage temperature
[°C]
-25...70 °
Operating temperature
[°C]
-10...45 °
Model / protective system
IP20
Relative humidity
max. 95% without condensation
Tested in accordance with...
EN 61800-3
Climatic category
3K3 in accordance with EN 50178
(10-17)