4
3
KEB COMBIVERT F4-F
10
Name: Basis
15.12.98
CP - Parameter
©
KEB Antriebstechnik, 1998
All Rights reserved
Operation
Chapter
Section
Page
Date
Defines the maximum setpoint speed.
Adjustment Range:
0…9999,5
rpm
Resolution:
0,5
rpm
Factory setting:
2100
rpm
Customer setting:
________
rpm
Only the reference speed is limited by this parameter. The actual
speed can exceed this value because of control oscillations or a
fault in the speed detection.
Maximum Setpoint Speed
Analoge setpoint presetting: REF 1
terminals X2.14 + X2.15
CP.10
+10
0
Analog setpoint
[rpm]
U [V]
(REF 1)
Specifies a jogging speed (fixed speed), which can be activated by the digital inputs
I1 (forward) or I2 (reverse). If both rotations are simultaneously preset, 'forward' has
priority.
Adjustment Range:
0…9999,5
rpm
Resolution:
0,5
rpm
Factory setting:
100
rpm
Customer setting:
________
rpm
Function:
I1 or I2 active
⇒
The drive runs with an adjusted jogging speed.
- The original direction of rotation, speed, acceleration and decleration times do not
have a function!
- ACC and DEC times only have limited functions (see the following table)!
- If the jogging speed entered is too high, the adjusted value is internally limited onto
the maximum permissible motor speed!
- The software limit switches (see CP.35) remain active!
I1 and I2 not active
⇒
The drive runs with the analog reference speed.
Jog-Speed