11
ANTRIEBSTECHNIK
4
3
11
KEB COMBIVERT F4-F
Name: Basis
15.12.98
4
CP - Parameter
©
KEB Antriebstechnik, 1998
All Rights reserved
Operation
Chapter
Section
Page
Date
P-Factor Speed Controller
Proportional factor of the speed controller.
Adjustment Range:
0…65535
Resolution:
1
Factory setting:
400
Customer setting:
________
! see also parameter CP.36 !
I-Factor Speed Controller
Integral factor of the speed controller.
Adjustment Range:
0…65535
Resolution:
1
Factory setting:
200
Customer setting:
________
! see also parameter CP.36 !
Encoder 1 (inc/r)
Adjusts the increments of the incremental encoder used. Check the set and actual
speed displays during open-loop operation and compare.
The correct setting is: actual speed = set speed - slip
Adjustment Range:
256…10000
Resolution:
1
Factory setting:
2500
Customer setting:
________
Input
Speed Ratio
Acceleration/
I1 / I2
Deceleration Performance
is
Actual speed dis. (CP.1) <
drive accelerates on
activated
Jogging speed (CP.11)
the torque limit
is
Actual speed dis. (CP.1) >
drive accelerates in accord.
activated
Jogging speed (CP.11)
with the adjusted ramp
is
Speed reference dis. (CP.6) <
drive decelerates on
deactivated Jogging speed (CP.11)
the torque limit
is
Speed reference dis. (CP.6) > drive accelerates in accord.
deactivated Jogging speed (CP.11)
with the adjusted ramp