KEB COMBIVERT F4-F
14
Name: Basis
15.12.98
CP - Parameter
©
KEB Antriebstechnik, 1998
All Rights reserved
Operation
Chapter
Section
Page
Date
CP.17 adjusts a zero point hysteresis of the setpoint input REF1. Voltage fluctuations
and ripple voltages near the zero point of the setpoint do not cause the motor to shift.
Adjustment Range:
0…10
%
Resolution:
0,1
%
Factory setting:
0
%
Customer setting:
________
%
This function has a switching hysteresis of 50%. If the analog signal is larger than the
adjusted hysteresis value (CP.17), then the analog value is active. If the analog signal
goes below 50% of the adjusted hysteresis value (0.5 x CP.17), then the analog
setpoint is set at 0.
Zero Point Hysteresis REF 1
CP.17
0,5 x CP.17
Analog Signal
CP.17
0,5 x CP.17
t
t
Analog Signal
Preset
Analog Setpoint
Effective
Analog Setpoint
for CP.17 the
following is valid:
0…10 % = 0…±1 V
^