KEB COMBIVERT F4-F
Name: Basis
15.12.98
4
CP - Parameter
©
KEB Antriebstechnik, 1998
All Rights reserved
Operation
Chapter
Section
Page
Date
Value
Output Variable
Value Range when CP.19 = 1
0
Actual speed
-2 • n
fn
… +2 • n
fn
=
-10V … +10V
1
Motor apparent current
0 … 2 • I
SN
=
0 … +10V
2
Actual torque
-2 • M
N
… +2 • M
N
=
-10V … +10V
3
DC-bus voltage
0 … 1000 V
=
0 … +10V
4
Speed reference (CP.6)
-2 • n
fn
… +2 • n
fn
=
-10V … +10V
5
Control difference
-2 • n
fn
… +2 • n
fn
=
-10V … +10V
(speed controller)
6
Set torque
-2 • M
N
… +2 • M
N
=
-10V … +10V
7
Modulation depth
0...100 %
^
=
0… 10V
8
Position
- in the CP-Mode no funktion-
9
Speed in front of ramp
-2 • n
fn
… +2 • n
fn
^
=
-10V … +10V
10
REF1 output
-10V...+10V
^
=
-10V...+10V
Defines which variable is displayed on analog output 1 (terminal X2.18).
Adjustment Range:
0…10
Resolution:
1
Factory setting:
2
Customer setting:
________
Note:
ENTER-Parameter
Function Output A1
^
^
^
^
^
^
^
During open-loop operation (CP.32 = 0) the analog output A1
has no function with the values 2,5, and 6.
n
fn
:
Rated-Rotating Field Speed
M
N
:
Rated Torque
I
SN
:
Rated-Motor Apparent Current