Functional Description
Parameter Sets
6.7
Parameter Sets
6.7.2
Copying of Para-
meter Sets (Fr.0,
Fr.1, Fr.9)
The KEB COMBIVERT comprises 8 parameter sets (0…7), i.e. all programmable
parameters exist 8-times in the inverter and can be assigned independent of each
other with different values. Thus it is possible to approach 8 different positions in the
positioning module. Since a lot of the parameters in the parameter sets have the
same value it would be quite troublesome to adjust each parameter in every set. The
following section describes how to copy, lock and select complete parameter sets
and how to initialize the inverter again.
6.7.1
Non-
programmable
Parameters
Certain parameters are non-programmable, since their value must be the same in all
sets (e.g. bus address or baud rate). To identify these parameters immediately the
parameter set number is missing in the parameter identification.
The same value
applies to all non-programmable parameters independent of the selected
parameter set.
Fr.0
⇓
copying of
parameter sets by
keyboard
Fr.1 und Fr.9
⇓
copying of
parameter sets by
Bus
Adjustment of source and
target set by keyboard
0
✳
Fr
·
0
1
✳
Fr
·
0
2
✳
Fr
·
0
3
✳
Fr
·
0
4
✳
Fr
·
0
5
✳
Fr
·
0
6
✳
Fr
·
0
7
✳
Fr
·
0
▲
DOWN
UP
▼
Adjust target set
At blinking parameter set number the
target set 0…7 is adjusted with the
keys UP/DOWN. During copying the
active parameter set (A) may not be
adjusted as target set. If the target
set is > 0, only the programmable
sets are overwritten.
A
✳
Fr
·
0
1
2
3
4
5
6
7
▲
DOWN
UP
▼
Adjust source set
With the keys UP/DOWN the initialization
set, default set of set 0…7 is adjusted.
- At „init“ all parameters in every set are
overwritten with the factory setting.
- At „def“ the target set is overwritten with
the factory setting.
- At „0...7“ the selected parameter set is
copied into the target set. If the set is > 0,
then only the programmable parameters
are copied into the target set.
0
def
init
➱
Changeover to source
with Funct.
Starting of copying
If the source set is selected, the copying process can be started with „ENTER“. If the
copying process is successfully completed the display shows „Pass“, otherwise the
message „nco“ (no copy) appears.
By loading the factory setting
all definitions defined by the
machine builder are reset!
This can include the terminal
assignment, set changeover or
operating conditions. Prior to
loading the initialization set or
default set make certain that no
unintended operating conditions
occur.