17
ANTRIEBSTECHNIK
6
11
17
KEB COMBIVERT F4-F
Name: Basis
17.06.99
6
Section
Page
Date
©
KEB Antriebstechnik, 1999
All Rights reserved
Chapter
Functional Description
Positioning Module
6.11.18 Check List
1
Positioning module activated
Pc.0 = 1
2
Select mode of position setting
(increments / revolutions)
Pc.1
3
Parameter set selection activated
Fr.2 = 1...3
4
Inputs for selection of positions
(parameter sets) defined
di.3...di.12 = 1
5
Reference point approach defined or disabled
Pc.10..Pc.14,
di.3...di.12
6
Positioning in the individual sets enabled / disabled
Pd.0
7
Setpoint positions and traversing mode defined
Pd.8...Pd.11
in the sets
8
Drive profile for the approach of the positions defined
Pd.5...Pd.7
9
Target window defined
Pd.12
10
Software-limit positions adjusted or disabled
Pc.4...Pc.9
11
Hardware-limit switch activated
di.3...di.6,
di.11...di.12, Pn.24
12
Starting command for positioning defined
di.3...di.6,
di.11...di.12
13
Speed controller and position controller adjusted
CS.0, CS.1, Pd.2,
Pd.3
14
If necessary, program digital output
(e.g. target window reached)
do.-Par.