7
ANTRIEBSTECHNIK
6
3
7
KEB COMBIVERT F4-F
Name: Basis
02.03.99
6
Section
Page
Date
©
KEB Antriebstechnik, 1999
All Rights reserved
Chapter
Functional Description
Digital In- and Outputs
di.3...di.12 Function
0
no function
1
parameter set selection
2
reset to set 0 for input-coded parameter set selection
3
to trip an external error
4
jogging clockwise rotation
5
jogging counter-clockwise rotation
6
resetting of angular displacement
7
position correction of slave positive (only synchronous module)
8
position correction of slave negative (only synchronous module)
9
to deactivate synchronous control (only synchronous module)
10
reference point operation clockwise rotation
11
reference point operation counter-clockwise rotation
12
reference point switch
13
motorpotentiometer - increase value (see „Motorpoti“)
14
motorpotentiometer - decrease value (see „Motorpoti“)
15
Reset
1)
16
rotation forward
17
rotation reverse
18
limit switch both directions (no reference point operation possible)
19
start positioning (only positioning module)
20
rotation forward and reference point switch
21
rotation reverse and reference point switch
22
positoning deactivated (only positioning module)
1)
If no input is programmed to function Reset then a Reset is automatically triggered
upon opening the control release (if an error exists). When one input has the
function Reset, then it is not possible to trip a reset with the control release.
t
t
t
t
Fig. 6.3.7.b Static strobe
Strobe input
resultant strobe
signal
Terminal status
Input status
6.3.8
Function
Assignment
(di.3...di.12)
With the following parameters the desired functions are assigned to the programmable
inputs I1...I6 and the internal inputs IA...ID.
di.3
di.4
di.5
di.6
di.7
di.8
di.9 di.10 di.11 di.12
⇓⇓⇓⇓⇓
⇓⇓⇓⇓⇓
⇓⇓⇓⇓⇓
⇓⇓⇓⇓⇓
⇓⇓⇓⇓⇓
⇓⇓⇓⇓⇓
⇓⇓⇓⇓⇓
⇓⇓⇓⇓⇓
⇓⇓⇓⇓⇓
⇓⇓⇓⇓⇓
I1
I2
I3
I4
IA
IB
IC
ID
I5
I6
Following table lists the possible functions and the matching decimal values. To adjust
a function the decimal value of the parameter must be set.