9
ANTRIEBSTECHNIK
4
3
9
KEB COMBIVERT F4-F
Name: Basis
15.12.98
4
CP - Parameter
©
KEB Antriebstechnik, 1998
All Rights reserved
Operation
Chapter
Section
Page
Date
The maximum torque of the drive is limited by the following:
n
fn
Nominal-Rotating Field Speed
U
rated
Inverter Rated Voltage
CP.30
Motor Rated Voltage
U
rated
n
1
= 0,6 x n
fn
x
CP.30
U
rated
n
2
= 0,86 x n
fn
x
CP.30
Torque
[Nm]
Speed
[rpm]
n
1
torque limit
(CP.9)
maximum torque
1,5 x M
rated
(Motor)
n
2
– Dimensioning
KEB COMBIVERT – Motor
If KEB COMIBVERT is dimensioned too small the torque is automatically limited
due to a motor current which is too low.
– Programming the Motor Parameters CP.25 - CP.30
Dependent on the adjusted motor data a speed-dependent limit curve (see below)
is set. The value of the calculated maximum torque is automatically written in
parameter CP.9
Parameter CP.31 (Load motor dependent parameter) activates the motor data and
the respective limit curve.
See table on page 23 for the factory setting of the motor parameter!