6.1.4 Description of ru-Parameter
ru. 0
Inverter state
ru-Parameter
In parameter „inverter status“ the actual operating condition of the frequency inverter is displayed. The operating conditions
can be devided into four groups:
1. Ready for operation signals
2. Process signals
3. Fault signals
4. Error messages
1. Ready for operation signals
These signals are given upon completion of initialization and when the frequency inverter is ready for operation:
Display
Bus
Meaning
noP
0
no Operation
- control release (terminal X2.1) not activated
- modulation disabled
- output voltage = 0 V/drive without control
LS
70
Low Speed
- control release (terminal X2.1) active
- rotation setting is missing
- modulation disabled
- output voltage = 0 V/drive without control
2. Process signals
The signals occur during the normal operation of the frequency inverter:
Display
Bus
Meaning
(drive conditions refer to the setpoint value)
FAcc
64
Forward Acceleration
- drive accelerates with rotation forward
FdEc
65
Forward Deceleration
- drive decelerates with rotation forward
Fcon
66
Forward Constant
- drive operates with constant speed and rotation forward
rAcc
67
Reverse Acceleration
- drive accelerates with rotation reverse
rdEc
68
Reverse Deceleration
- drvie decelerates with rotation reverse
rcon
69
Reverse Constant
- drive operates with constant speed and rotation reverse
rFP
79
Ready for Positioning
- positioning module active
- drive is in „off“-positon and waits for positioning command
PA
80
Positioning Active
- positioning module active
- drive carries out positioning command
SrA
82
Search for
- positioning or synchronous module active
Reference Active
- drive performs reference point run