6.12.4 Example
For example a user menu shall be programmed with following characteristics:
1. Display of actual frequency (ru.1) in the respective set
2. Absolute digital setpoint setting (SP. 1) in set 2
3. Absolute digital setpoint setting (SP. 1) in set 3
4. Acceleration and deceleration time (SP.11/SP.12) in the respective active set
5. On switch on the active parameter set (ru.18) shall be displayed
1.)
ud.15 = 2001
; Parameter address for ru.1
ud.16 = A
; Display in the active set
2.)
ud.17 = 3001
; Parameter address for SP. 1
ud.18 = 2
; Preadjustment in set 2
3.)
ud.19 = 3001
; Parameter address for SP. 1
ud.20 = 3
; Preadjustment in set 3
4.)
ud.21 = 300B
; Parameter address for SP.11
ud.22 = A
; Preadjustment in the respective set active at the time
ud.23 = 300C
; Parameter address for SP.12
ud.24 = A
; Preadjustment in the respective set active at the time
5.)
ud.27 = 2012
; Parameter address for ru.18
ud.28 = A
; Display in the active set
ud.2 = 1
; Disply of ru-Parameter (by activating the CP-mode this
; this setting is ignored)
ud.3 = 7
; Display of CP.7
adjust all other parameter addresses to „off“ so that no indication occurs.
6.12.5 Used Parameters
ud.0
2600h
✔
-
✔
0
9999
1
cp_on
-
ud.1
2601h
✔
-
-
-32767
32767
1
cp_on
only visible by bus
ud.2
2602h
✔
-
-
1(ru)
16(Pd)
1
1 (ru)
ru/SP/Pn/dr/cs/ds/ud/Fr/An/di/do/LE/In/Sn/Pc/PdAA
ud.3
2603h
✔
-
-
0
*255
*1
1
* dependent on parameter group
ud.13
260Dh
-
-
-
-
-
-
-
only visible by bus
ud.14
260Eh
-
-
-
-
-
-
-
only visible by bus
ud.15
260Fh
✔
-
✔
-1 (off)
7FFF
1
2001
corresponds to ru.1
ud.16
2610h
✔
-
✔
0
8
1
0
set 0...7; A(8) = active set