3
ANTRIEBSTECHNIK
6
5
3
KEB COMBIVERT F4-F
Name: Basis
11.05.99
6
Section
Page
Date
©
KEB Antriebstechnik, 1999
All Rights reserved
Chapter
Functional Description
Motor Data and Controller Adjustment
ANTRIEBSTECHNIK
KEB Antriebstechnik
GmbH & Co. KG
Schneeberg
Made in
Germany
-Mot IP
IM
W.KI.
°C
kg
Hz
V
cos
/Y
1/min
U
V
~Mot
Hz
Nm
mm
FL
M
Br
I
Sp max
DK 160 L 4 F I
/TW150
96/1632804/ 001
3
55
B 3
F
40
127
VDE 053 0
15,0 KW
ϕ
50
230/400
0,86
1455
230/400
3
50
49,5/28,5 A
IGR 05B 2500 Imp
5V D0/RS 6xTTL
dr.1
dr.2
dr.3
dr.4
dr.12
dr.0
6.5
Motor Data and
Controller
Adjustment
Fig. 6.5.1
Example of a motor name plate
6.5.1
Motor Name Plate
The adjustment of the correct motor data is important for a lot of inverter functions,
since this data is used for calculations which are needed by the inverter. Wrong settings
can cause control oscillations and uncontrollable behaviour of the drive.
6.5.2
Motor Data from
Name Plate
(dr.0...dr.4, dr.12)
Following parameters can be taken directly from the name plate (see above) and
entered:
- dr.0
Rated motor power
0,01...75kW
- dr.1
Rated motor speed
100...9999 U/min
- dr.2
Rated motor current
0,1...1,1 x In.01 (delta / star connection)
- dr.3
Rated motor frequency
20...300 Hz
- dr.4
Rated motor output factor 0,05...1,00
- dr.12 Rated motor voltage
100...500 V (delta / star connection)
Parameter dr.2 and dr.12 must always be adjusted in accordance with the used
connection (star or delta). This means for the above motor name plate that it is
230 V / 48,5A for delta connection and 400 V / 28,5 A for star connection. It
doesn’t matter that for example the rated output voltage of the inverter is larger
(see „87Hz-chracteristic“).