2
8
6
Name: Basis
KEB COMBIVERT F4-F
17.09.98
Functional Description
Analog In- and Outputs
Chapter
Section
Page
Date
©
KEB Antriebstechnik, 1998
All Rights reserved
+100%
+100%
-100%
-100%
An.3
+100%
+100%
-100%
-100%
An.4
+75%
1.
2.
An.3 = +1, An.4 = 0%, An.5 = 0%
An.3 = -1
, An.4 = 0%, An.5 = 0%
An.3 = -1, An.4 = 0%, An.5 = 0%
An.3 = -1,
An.4 = +75%
, An.5 = 0%
+100%
+100%
-100%
-100%
An.5
+100%
3.
An.3 = -1, An.4 = +75%, An.5 = 0%
An.3 = -1, An.4 = +75%,
An.5 = +100%
Fig. 6.2.7
Gain (An.3)= -1, X-Offset (An.4)= +75%, Y-Offset (An.5)= +100%
Example 2:
Following values shall be adjusted for the input REF1 ± :
1. Gain adjusted to -1 (single amplification)
2. X-Offset adjusted to 75 %
3. Y-Offset adjusted to 100 %
With these settings and inverted setpoint setting in the range of +75...+100 % IN by
way of input REF1 ± a speed range of +100...+75% OUT can be driven, that means:
0% IN
correspond to
+100% OUT
+75% IN
correspond to
+100% OUT
+100% IN
correspond to
+75% OUT
To avoid the wrong programming of the analog input signals the IN / OUT adaption