15
ANTRIEBSTECHNIK
6
1
15
16.03.99
KEB COMBIVERT F4-F
Name: Basis
6
Functional Description
©
KEB Antriebstechnik, 1999
All Rights reserved
Chapter
Section
Page
Date
Only active at activated positioning module!!! Indicates with ru.36 the absolute setpoint position from the reference
point. Depending on Pc.1 following representation is possible:
When displayed in increments (Pc.1 = 0 or 1) increments in a range of 0...9999 are displayed.
When displayed in rotations (Pc.1 = 2 or 3) partial rotations in a range of 0...65535 are displayed. (1 rotation = 65535)
2025h
1
inc
9999 (65535)
0
Adr.
min
max
default
Adr.
min
max
default
2026h
1
-
-
1
0
Adr.
min
max
default
2027h
1
inc
-
65535
0 (-65535)
Adr.
min
max
default
2028h
1
inc
9999 (65535)
0
ru-Parameter
-
ru.37 Actual position low
Only active at activated positioning module!!! Indicates with ru.36 the absolute actual position from the reference point.
Depending on Pc.1 following representation is possible:
When displayed in increments (Pc.1 = 0 or 1) increments in a range of 0...9999 are displayed.
When displayed in rotations (Pc.1 = 2 or 3) partial rotations in a range of 0...65535 are displayed. (1 rotation = 65535)
ru.38 Set position sign
ru.39 Set position high
Only active at activated positioning module!!! Indicates the absolute setpoint position from the reference point. Depending
on Pc.1 following representation is possible:
When display in increments (Pc.1 = 0 or 1) the displayed value must be multiplied with 10000 Inc.
When display in rotations (Pc.1 = 2 or 3) the displayed value is correspond to coplete motor rotations.
depend on Pc.1
depend on Pc.1
-
ru.40 Set position low
Only active at activated positioning module!!! Indicates at decimal position display (Pc.1 = 0 or 1) the sign of the
setpoint position. At hexadecimal display (Pc.1 = 2 or 3) the parameter is without function.
0:
Setpoint position in positive direction from the reference point
1:
Setpoint position in negative direction from the reference point
2:
Without function since hexadecimal display is selected
depend on Pc.1