ANTRIEBSTECHNIK
6
2
13
KEB COMBIVERT F4-F
Name: Basis
17.09.98
Functional Description
Analog In- and Outputs
Chapter
Section
Page
Date
©
KEB Antriebstechnik, 1998
All Rights reserved
6
+10 V
+100%
-10 V
-100%
An.19
An.19 = 1, An.20 = 0 %
An.19 = 20
, An.20 = 0 %
Because of the high adjustment of the gain the change of the output voltage from -
10V to +10V takes place within a very small alteration range of the variable to be
indicated. Thus the output can be used as „switch“ (HI- and Low-level) for some
applications. The adjustment of the X-Offset determines the „switching level“.
This means:
0...20 %
of the variable to be indicated correspond to
-10 V at A2
20...30 %
of the variable to be indicated correspond to -10...+10 V at A2
30...100 %
of the variable to be indicated correspond to
+10 V at A2
Fig. 6.2.14
Gain (An.19) = 20,00 and X-Offset (An.20) = 25 %,
Example 2:
Following values shall be adjusted for the output A2:
1. Gain adjusted to 20 (-times amplification)
2. X-Offset adjusted to 25 %
+10 V
+100%
-10 V
-100%
An.20
+20%
+25%
+30%
1.
2.
An.19 = 20, An.20 = 0 %
An.19 = 20,
An.4 = +25 %
variable to be indicated
variable to be indicated
A1
A1