4
3
KEB COMBIVERT F4-F
4
Name: Basis
15.12.98
CP - Parameter
©
KEB Antriebstechnik, 1998
All Rights reserved
Operation
Chapter
Section
Page
Date
Parameter
Parameter Describtion
Adjustment
Resolution
Factory Setting
Number
Range
CP.0
Password Input
0…9999
1
–
CP.1
Actual speed display
1)
–
0,5 rpm
–
CP.2
Status display
–
–
–
CP.3
Apparent motor current
1)
–
0,1
A
–
CP.4
Max. apparent motor current
1)
–
0,1
A
–
CP.5
Actual torque display
1)
–
0,1
Nm
–
CP.6
Speed reference display
1)
–
0,5 rpm
–
CP.7
Acceleration time
0…320
s
0,01
s
2,0
s
CP.8
Deceleration time
0…320
s
0,01
s
2,0
s
CP.9
Torque limit
2)
0…5 x M
N
Nm
0,1
Nm
dependent on size
CP.10
Maximum setpoint speed
0…9999,5 rpm
0,5 rpm
2100 rpm
CP.11
Jogging speed
0…9999,5 rpm
0,5 rpm
100 rpm
CP.12
P-factor speed controller
0…65535
1
400
CP.13
I-factor speed controller
0…65535
1
200
CP.14
Encoder 1 (inc/r)
256…10000
1
2500
CP.15
Behaviour at external fault
0…6
1
0
CP.16
Offset REF 1
-100…+100
%
0,1
%
0
%
CP.17
Zero point hysteresis REF 1
0…10
%
0,1
%
0,2
%
CP.18
Function output A1
0…10
1
2
CP.19
Gain output A1
-20…+20
0,01
1
CP.20
Gain output A2
-20…+20
0,01
1
CP.21
Output condition D1
0…33
1
20
CP.22
Output condition D2
0…33
1
18
CP.23
Torque level D1
1)
0…2000
Nm
0,1
Nm
0
Nm
CP.24
Speed level D2
1)
0…9999,5 rpm
0,5 rpm
0 rpm
CP.25
Rated motor power
2)
0,01...75
kW
0,01
kW
dependent on size
CP.26
Rated motor speed
2)
100...9999,5 rpm
1 rpm
dependent on size
CP.27
Rated motor current
2)
0,1...50
A
0,1
A
dependent on size
CP.28
Rated motor frequency
20...300
Hz
1
Hz
dependent on size
CP.29
Rated motor cos (Phi)
2)
0,05...1
0,01
dependent on size
CP.30
Rated motor voltage
100...400
V
1
V
400
V
CP.31
Load motor dependent parameter
0...2
1
0
CP.32
Speed control on/off
0...1
1
0
CP.33
Boost
0...25,5
%
0,1
%
2
%
CP.34
Change encoder 1 rotation
0...1
1
0
CP.35
Reaction to limit switch
0...6
1
6
CP.36
Aux function
0...96
1
0
1)
Resolution means the program internal resolution of parameters.
The accuracy of the detection / calculation of the parameter values may be worse than the resolution.
2)
See table for parameter values that are dependent on the size (page GB 35)!
Due to the calculation / measuring accuracies, tolerances with the current and torque displays as well as with the
switching levels and limitations, must be taken into consideration. The given tolerances (see parameter
description) refer to the respective maximum values with the dimensioning KEB COMBIVERT: Motor = 1:1.
Dependent on the data from the motor manufacturer, larger tolerances at the torque displays are possible,
due to the usual variations in the machine parameters and temperature drifts.