Functional Description
Encoder Interface
dr.25
2419h
✔
-
✔
256
10000
1
2500
increments / revolution
dr.28
241Ch
✔
-
✔
0
1
1
0
1 only for sine / cosine encoder
dr.29
241Dh
✔
-
✔
0
1
1
0
-
dr.30
241Eh
✔
-
✔
256
10000
1
2500
increments / revolution
dr.31
241Fh
✔
-
-
0
13
1
0
-
dr.32
2420h
✔
-
-
0
1
1
0
-
dr.33
2421h
✔
-
-
0
1
1
0
-
dr.34
2422h
✔
-
✔
0
1
1
0
-
dr.39
2427h
✔
-
✔
0
1
1
1
1 = incremental encoder input
dr.40
2428h
✔
-
✔
0
5
1
3
-
Param.
Adr.
min
max
default
ENTER
PROG.
R/W
Step
6.9.7
Used Parameters
6.9.6
Power Supply
of Encoder
18 V
X4 /
15 pol.
SNT
X2
13
Step
Down
X5
5 V
0 V
15 V
X4 /
15 pol.
SNT
X2
13
Step
Down
X5
Step
Down
ExtGND
GND
5 V
0 V
18 V
5 V
23
11
Fig. 6.9.6 Power supply
up to housing size E
as of housing size G
Generally applicable statement with regard to the power supply:
The internal 15V or 18V power supply at X4 and X5 can be loaded altogether with max.
110mA. If higher currents are required; an external voltage can be used.
The 5V-power supply is loadable with altogether 300mA