19
ANTRIEBSTECHNIK
6
1
19
16.03.99
KEB COMBIVERT F4-F
Name: Basis
6
Functional Description
©
KEB Antriebstechnik, 1999
All Rights reserved
Chapter
Section
Page
Date
Adr.
min
max
default
2C38h
1
-
0
7
0
Adr.
min
max
default
2C37h
0,1
-
-
-
-
Adr.
min
max
default
2C39h
1
-
0
7
0
In-Parameter
Indicates the software date of the control processor. The value incorporates date, month and year, at that only the last
number of the year is indicated.
Example:
Display= 1507.8
Date = 15.07.98
In. 55 Software date DSP
In.57 Feedback-system channel 2
This parameter indicates for which feedback system the inverter is suited on channel 2.
0:
incremental encoder input
1:
synchronous-serial interface (SSI)
2...3: - reserved -
4:
incremental encoder output (the input signals of channel 1 are given out on channel 2)
5..6: - reserved -
7:
changeable incremental encoder input / -output
In.56 Feedback-system channel 1
This parameter indicates for which feedback system the inverter is suited on channel 1.
0:
incremental encoder input
1...7: - reserved -