Name: Basis
Functional Description
Set Value and Ramp Adjustment
Chapter
Section
Page
Date
©
KEB Antriebstechnik, 1999
All Rights reserved
16.03.99
Example 1:
The drive shall meet following acceleration and deceleration values:
Rotation clockwise:
acceleration from 0 U/min
to 500 U/min in
2,5 s
(SP.11)
deceleration from 500 U/min
to 0 U/min in
2,5 s
(SP.12)
Rotation counter-clockwise:
acceleration from 0 U/min
to 800 U/min in
7,2 s
(SP.13)
deceleration from 800 U/min
to 0 U/min in
7,2 s
(SP.14)
For that the calculated values listed below must be entered in the parameters SP.11...SP.14
∆
t
SP.11
= ——
x 1000 U/min
with
∆
n = (500 U/min - 0 U/min) = 500 U/min and
∆
t = 2,5 s
∆
n
2,5 s
SP.11
=
—————
x
1000 U/min
=
5 s
500 U/min
2,5 s
SP.12
=
—————
x
1000 U/min
=
5 s
500 U/min
7,2 s
SP.13
=
—————
x
1000 U/min
=
9 s
800 U/min
7,2 s
SP.14
=
—————
x
1000 U/min
=
9 s
800 U/min
Example 2:
The drive shall meet the following acceleration and deceleration values:
Rotation clockwise:
acceleration from 0 U/min
to 500 U/min in
2,5 s
(SP.11)
deceleration from 500 U/min
to 0 U/min in
5,0 s
(SP.12)
Rotation counter-clockwise:
acceleration from 0 U/min
to 500 U/min in
2,5 s
(SP.13)
deceleration from 500 U/min
to 0 U/min in
5,0 s
(SP.14)
For that the calculated values listed below must be entered in the parameters SP.11...SP.14:
2,5 s
SP.11
=
—————
x
1000 U/min
=
5 s
500 U/min
5,0 s
SP.12
=
—————
x
1000 U/min
=
10 s
500 U/min
2,5 s
SP.13
=
—————
x
1000 U/min
=
5 s
(or enter off, as SP.11 = SP.13)
500 U/min
5,0 s
SP.14
=
—————
x
1000 U/min
=
10 s
(or enter off, as SP.12 = SP.14)
500 U/min