21
ANTRIEBSTECHNIK
4
3
21
KEB COMBIVERT F4-F
Name: Basis
15.12.98
4
CP - Parameter
©
KEB Antriebstechnik, 1998
All Rights reserved
Operation
Chapter
Section
Page
Date
Adjusts the direction of rotation of the encoder.
Adjustment Range:
0…1
Resolution:
1
Factory setting:
0
Customer setting
________
0
=
track
not
exchanged
1
=
track exchanged
Change Encoder 1 Rotation
This parameter determines the reaction of the drive, to terminal X2.3 (
F
) and/or X2.4
(
R
). These terminals can be programmed as software limit switches. The reaction of
the drive is shown in the table below.
Adjustment Range:
0…6
Resolution:
1
Factory setting:
6
Customer setting:
________
Reaction to Limit Switch
Value
Error / Status
Response of the drive
massage
0
E.PrF
modulation immediately switched off
E.Prr
!
To restart remove error and
activate
Reset !
1
A.PrF
quick stop / modulation switched off
A.Prr
after speed 0 is reached
!
To restart remove error and
activate
Reset !
2
A.PrF
quick stop / holding tourqe at speed 0
A.Prr
!
To restart remove error and
activate
Reset !
3
A.PrF
modulation immediately switched off
A.Prr
!
Automatic restart
, when error is no longer
present
!
4
A.PrF
quick stop / modulation switched off
A.Prr
after speed 0 is reached
!
Automatic restart
, when error is no longer
present
!
5
A.PrF
quick stop / holding tourqe at speed 0
A.Prr
!
Automatic restart
, when error is no longer
present
!
6
keine
no effect on the drive
!
Fault is ignored
!
Quick stop
⇒
⇒
⇒
⇒
⇒
deceleration at the torque limit (CP.9)