Parameter
5
1
KEB COMBIVERT F4-C
6
Name: Basis
Chapter
Section
Page
Date
©
KEB Antriebstechnik, 1999
All Rights reserved
21.06.99
Pn 16
E.dOH delay time
2210
-
-
✓
0
120
1
0
sec
6.3.10, 6.6.3, 6.6.4
Pn 17
power off start voltage
2211
-
✓
✓
198
800
1
198
––
6.8.13
Pn 20
extern fault stopping condition
2214
-
✓
✓
0
6
1
0
––
6.6.4
Pn 23
E.bus stopping condition
2217
-
✓
✓
0
6
1
6
––
11.2.3
Pn 24
prohibited rotation stopping condition
2218
-
✓
✓
0
6
1
6
––
6.11.7
Pn 25
warning dOH stopping condition
2219
-
✓
✓
0
6
1
6
––
6.6.3
Pn 26
warning OH stopping condition
221A
-
✓
✓
0
6
1
6
––
6.6.3
Pn 33
power off mode
2221
-
✓
✓
1
2
1
2
––
6.8.13
Pn 60
torque for abnormal stop
223C
-
✓
✓
0,0
5 x dr.09
0,1
?
Nm
6.8.13
dr - Parameter
Addr.
min
max
default
[?]
see Page(s)
dr
0
rated motor power
2400
-
✓
✓
0 ,01
75
0,01
*)
kW
6.5.3
dr
1
rated motor speed
2401
-
✓
✓
100
9999
1
*)
rpm
6.5.3
dr
2
rated motor current
2402
-
✓
✓
0,1
1,1 x In.1
0,1
*)
A
6.5.3
dr
3
rated motor frequency
2403
-
✓
✓
20
300
1
50
Hz
6.5.3, 6.5.5
dr
4
rated motor cos (phi)
2404
-
✓
✓
0,05
1,00
0,01
*)
––
6.5.3
dr
9
rated motor torque
2409
-
-
-
0,1
1000,0
0,1
––
Nm
6.5.11
dr 10
maximum torque
240A
-
-
-
0,1
1000,0
0,1
––
Nm
6.5.5, 6.5.11
dr 12
rated motor voltage
240C
-
✓
✓
100
500
1
400
V
6.5.3, 6.5.5
dr 13
speed for maximum torque
240D
-
✓
✓
0,0
9999,5
0,5
1000,0
rpm
6.5.5, 6.5.11
dr 16
maximum torque corner speed
2410
-
✓
✓
0,0
5 x dr.09
0,1
1,5 x dr.09 *)
Nm
6.5.5, 6.5.11
dr 19
corner speed field weakening
2413
-
✓
✓
200,0
9999,5
0,5
1300,0
rpm
6.5.6, 6.5.12
dr 20
field weakening curve
2414
-
✓
✓
0,10
2,00
0,01
1,20
––
6.5.12
dr 21
flux adaption factor
2415
-
✓
✓
25
250
1
100
%
6.5.12
dr 25
encoder 1 (inc/r)
2419
-
✓
✓
256
10000
1
2500
inc/r
6.9.8
dr 28
encoder 1 counter mode
241C
-
✓
✓
0
1
1
0
––
6.9.8
dr 29
change encoder 1 rotation
241D
-
✓
✓
0
1
1
0
––
6.9.8
dr 30
encoder 2 (inc/r)
241E
-
✓
✓
256
10000
1
2500
inc/r
6.9.8
dr 31
multiturn resolution encoder 2
241F
-
-
✓
0
13
1
0
––
6.9.7
dr 32
encoder 2 clock frequency
2420
-
-
✓
0
1
1
0
––
6.9.7
dr 32
encoder 2 code
2421
-
-
✓
0
1
1
0
––
6.9.7
dr 34
change encoder 2 rotation
2422
-
✓
✓
0
1
1
0
––
6.9.8
dr 39
encoder 2 mode
2427
-
✓
✓
0
1
1
1
––
6.9.6
dr 40
time for speed calculation
2428
-
✓
✓
0
5
1
3
––
6.9.8
dr 50
stator resistance
2432
-
✓
✓
0,000
32,767
0,001
1,100
Ohm
6.5.13
dr 51
leakage reactance
2433
-
✓
✓
0,00
327,67
0,01
10,58
mH
6.5.13
dr 52
motor connection
2434
-
✓
✓
0
1
1
1
––
6.5.13
CS - Parameter
Addr.
min
max
default
[?]
see Page(s)
CS 0
KP speed
2D00
✓
-
✓
0
32767
1
400
––
6.5.10
CS 1
KI speed
2D01
✓
-
✓
0
32767
1
200
––
6.5.10
CS 3
KP speed gain
2D03
-
-
✓
0
32767
1
0
––
6.5.10
CS 4
KP speed limit
2D04
-
-
✓
0
32767
1
0
––
6.5.10
CS 6
torque limit forward positive
2D06
✓
-
✓
0,0
5 x dr.9
0,1
dr.10
Nm
6.5.11
CS 7
torque limit reverse positive
2D07
✓
-
✓
-0,1 : off
5 x dr.9
0,1
-0,1 : off
Nm
6.5.11
CS 8
torque limit forward negative
2D08
✓
-
✓
-0,1 : off
5 x dr.9
0,1
-0,1 : off
Nm
6.5.11
CS 9
torque limit reverse negative
2D09
✓
-
✓
-0,1 : off
5 x dr.9
0,1
-0,1 : off
Nm
6.5.11
CS 10
aktivation of adaptation
2D0A
-
-
✓
0
65535
1
0
––
6.5.13
CS 11
KI offset
2D0B
-
-
✓
0
65535
1
0
––
6.5.10
CS 12
max speed for max Ki
2D0C
-
-
✓
0,0
9999,5
0,5
10,0
rpm
6.5.10
CS 13
min. speed for Cs.01
2D0D
-
-
✓
0,0
9999,5
0,5
500,0
rpm
6.5.10
CS 14
standstill position control
2D0E
-
-
✓
0
65535
1
0
––
6.5.10
CS 19
KP flux
2D13
-
-
✓
0 : off
65535
1
0 : off
––
6.5.12
CS 20
KI flux
2D14
-
-
✓
1
65535
1
1
––
6.5.12
CS 21
magn. current limit
2D15
-
-
✓
0,0
In.1
0,1
0,0
A
6.5.12
CS 22
flux mode
2D16
-
✓
✓
0
1
1
0
––
6.5.13
CS 23
speed regulation active
2D17
✓
✓
✓
0 : off
1
1
0 : off
––
6.5.5
ds - Parameter
Addr.
min
max
default
[?]
see Page(s)
ds
0
KP I active
2F00
-
-
✓
1
65535
1
1500
––
6.5.9
ds
1
KI I active
2F01
-
-
✓
1
65535
1
500
––
6.5.9
ds
5
KP I magnetizing
2F05
-
-
✓
0
65535
1
-1 : off
––
6.5.9
ds
6
KI I magnetizing
2F06
-
-
✓
0
65535
1
-1 : off
––
6.5.9
ds
9
no load voltage
2F09
-
-
✓
0,0
100,0
0,1
75,0
%
6.5.9
ds 10
DC voltage compensation
2F0A
-
✓
✓
180
500
1
501 : off
V
6.5.6
ds 11
boost
2F0B
-
-
✓
0,0
25,5
0,1
2,0
%
6.5.6
ds 12
modulation depth
2F0C
-
-
-
0
100
1
%
6.5.8
ds 13
carrier frequency
2F0D
-
✓
✓
0
1
1
0
––
6.5.8
ds 14
overmodulation
2F0E
-
✓
✓
0
1
1
1
––
6.5.8
dS 15
Adaption factor
2F0F
-
-
-
0,0 : off
100,0
0,1
-
%
6.5.14
ud - Parameter
Addr.
min
max
default
[?]
see Page(s)
ud
0
key password input
2600
-
✓
✓
0
9999
1
cp_on
––
4.4.3
ud
1
bus password input
2601
-
-
✓
-32767
32767
1
cp_on
––
6.12.5
ud
2
start parameter group
2602
-
-
✓
1 : ru
16 : Pd
1
1 : ru
––
6.12.4
ud
3
start parameter number
2603
-
-
✓
0
255
1
1
––
6.12.4
ud
6
inverter address
2606
-
✓
✓
0
239
1
1
––
11.2.3
ud
7
baud rate
2607
-
✓
✓
1200
57600
table
9600
Baud
11.2.3
*) dependent by the inverter size